YR80.242 Puls Redundancy Modules

YR80.242 on Automation Guru
Puls

Part#:YR80.242

Manufacturer:Puls

Category:Redundancy Modules

Product Lifecycle:Active

Product description

PULS YR80.242 is a redundancy unit from the Y-series designed with a built-in decoupling MOSFET for 1+1 or N+1 redundancy and ATEX approval. It operates with a supply voltage range of 8.4Vdc to 36.4Vdc, supporting nominal voltages of 12Vdc and 24Vdc. The unit measures 46mm in width, 124mm in height, and 127mm in depth, featuring screw-clamp connections for secure installation. It is rated for a current of 80A at 28Vdc, with a derating to 2A at temperatures ranging from +60°C to +70°C. Designed for DIN rail mounting, it can operate within an ambient air temperature range of -40°C to +70°C. The YR80.242 has a peak inrush current consumption of 1500A and offers protection functions including short-circuit protection with a 44A threshold at 6V. It supports series or parallel operation for 1+1 redundancy, utilizing two identical power supplies, or N+1 redundancy with three or more power supplies, ensuring continued operation following most single power supply failures. The output voltage is maintained between 12-28Vdc, with power dissipation/losses of 2.9W for 2x20A input and 4.6W for 40A input at 8.4-36.4Vdc. Its electrical durability is rated at 499,000 hours at 40°C with a 40A output from 2x20A input, and 1,410,000 hours at 25°C with an 80A output from 2x20A input. The output stage capacitance is 320µF, with a ripple of 65mVpp across a frequency range of 20Hz to 20MHz at 50Ω.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of YR80.242 on Automation Guru is $275.00. Order now.


Manufacturer warranty

YR80.242 Puls

$275.00

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$275.00

$275.00 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

About the manufacturer

Puls

Automation Guru is an authorized Puls distributor, proudly offering a comprehensive range of Puls products known for their outstanding reliability and efficiency in power supply solutions. Puls, a leading manufacturer, specializes in developing high-quality DIN rail power supplies that are essential in ensuring the uninterrupted operation and longevity of industrial automation systems. With a repu...

About the Product Category

A redundancy module is used to decouple two power supplies and ensures the high availability and productivity of your system. A redundant power supply is particularly necessary in applications with stringent demands regarding operational safety.

Redundancy Modules

Relevant products

CT5.241 on Automation Guru

CT5.241

Verified stock: 7

PULS CT5.241 is a DIN rail mounting power supply unit with an aluminium housing, designed for an ambient air temperature range of -25 to +70°C. It features a net width of 40mm and dimensions of W40mm x H124mm x D117mm. The unit consumes 0.68A with a 480Vac input and 0.75A with a 400Vac input for a full 24Vdc output, with a peak inrush current of 10A at both 480Vac and 400Vac inputs. It boasts an efficiency of 0.9 at 480Vac input and 0.904 at 400Vac input. The CT5.241 offers a 75ms start-up delay and a rise time of 35-36ms under nominal input with a constant full current load and 0mF load capacitance, extending to 64-68ms with 5mF load capacitance. It includes protection functions such as output overvoltage protection and an active input inrush current limiter, with overload/short-circuit protection up to 13A continuous current. The unit supports series/parallel operation for increased output power and is resistant to back-feeding loads up to 35V. Power dissipation/losses are 13.3W and 12.7W for 480Vac and 400Vac inputs, respectively, under full output load. The output stage capacitance is 3800µF, and the electrical durability ranges from 72,000 to 526,000 hours depending on the operating conditions. The ripple is specified at 50mVpp (20Hz...20MHz; 50Ω). This AC/DC power supply unit/converter, part of the CT-series, is designed with a 20% power reserve and includes a DC-OK relay contact output. It features screw-clamp connections and accepts a wide range supply voltage of 323Vac-576Vac (2-phase input) with various shutdown voltages based on load conditions. The rated current is 6A at 24Vdc from -25 to +45°C and 3.75A at 24Vdc from -25 to +70°C, with a rated power of 120W. The output voltage is adjustable from 24Vdc to 28Vdc, with a hold time of 60ms at 480Vac input and 40ms at 400Vac input.

Puls

FAQ

What is the price of YR80.242?
Purchase the YR80.242 from Automation Guru at the price of $275.00. Order today.

Out if stock but available for backorder.

PULS YR80.242 is a redundancy unit from the Y-series designed with a built-in decoupling MOSFET for 1+1 or N+1 redundancy and ATEX approval. It operates with a supply voltage range of 8.4Vdc to 36.4Vdc, supporting nominal voltages of 12Vdc and 24Vdc. The unit measures 46mm in width, 124mm in height, and 127mm in depth, featuring screw-clamp connections for secure installation. It is rated for a current of 80A at 28Vdc, with a derating to 2A at temperatures ranging from +60°C to +70°C. Designed for DIN rail mounting, it can operate within an ambient air temperature range of -40°C to +70°C. The YR80.242 has a peak inrush current consumption of 1500A and offers protection functions including short-circuit protection with a 44A threshold at 6V. It supports series or parallel operation for 1+1 redundancy, utilizing two identical power supplies, or N+1 redundancy with three or more power supplies, ensuring continued operation following most single power supply failures. The output voltage is maintained between 12-28Vdc, with power dissipation/losses of 2.9W for 2x20A input and 4.6W for 40A input at 8.4-36.4Vdc. Its electrical durability is rated at 499,000 hours at 40°C with a 40A output from 2x20A input, and 1,410,000 hours at 25°C with an 80A output from 2x20A input. The output stage capacitance is 320µF, with a ripple of 65mVpp across a frequency range of 20Hz to 20MHz at 50Ω.

What can I help you find today?

Recommended parts